Pollution click has high sensitivity to organic gases such as methanal (also known as formaldehyde), benzene, alcohol, toluene, etc. The click carries the WSP2110 VOC gas sensor with the detection range of 1~50ppm (parts per million).
Pollution click is designed to run on a 5V power supply. It communicates with the target MCU over AN and RST pin on the mikroBUSâ„¢ line.
WSP2110 VOC GAS SENSOR
WSP2110 VOC gas sensor is a MOS type (metal oxide semiconductor) sensor that detects volatile organic compounds such as methanal, benzene, alcohol and other types of gases that can be harmful to one’s health in high concentrations. The concentration of the target gas affects the conductivity of the sensor. Higher concentration of the gas means the conductivity of the sensor gets higher as well.
For precise calibration, the sensor needs to preheat (once powered up, it takes 120h to reach the right temperature).
Sensor’s Sensitivity
P1 potentiometer onboard is used for trimming the sensor’s sensitivity. Enable the pin drive gate of the heaters MOSFET switch to reduce power consumption when the click is not in use.
Detection Range
The detection range of the sensor is 1~50ppm (part per million). Parts per million is the number of parts of a component in 1 million parts of the gas mixture, it’s the ratio of one gas to another
Applications: Automatic exhaust devices, air cleaners, harmful gas detection devices, etc.
1 x Mikroe POLLUTION CLICK
Only logged in customers who have purchased this product may leave a review.
Shipping and Delivery Policy
1. Shipping Process:
2. Shipping Charges:
3. Order Tracking:
4. Delivery Address:
5. Delivery Issues:
6. No Return Policy for Opened/Soldered Products:
7. Refund Policy:
Out of stock
| Particle Measurement Range |
0.3~1.0μm; 1.0~2.5μm; 2.5~10μm |
|---|---|
| Particle Counting Efficiency |
50%@0.3μm ,98%@>=0.5μm |
| Resolution of Particle Mass Concentration |
1μg/mᶟ |
| Temperature Measurement Range |
0~99℃ |
| Temperature Measurement Resolution |
0.1℃ |
| Humidity Measurement Range |
0~99% |
| Humidity Measurement Resolution |
0.1% |
| Humidity Measurement Accuracy |
±2% |
| Single Response Time |
<1s |
| Comprehensive Response Time |
≤10s |
| DC Supply Voltage |
Typ: 5V Min: 4.5V Max: 5.5V |
| Working Current |
≤100mA |
| Standby Current |
≤200mA |
| Data Interface Level |
L<0.8V ,H>2.7V ,maximum level voltage 3.3V |
| Working Temperature Range |
10~50℃ |
| Working Humidity Range |
0~99% |
| Storage Temperature Range |
40~80℃ |
Out of stock
| Detection Gas |
Oxygen concentration |
|---|---|
| Detection range |
0~100% |
| Working Pressure Range |
0.5~2.0Bar |
| Working Voltage |
3.3~5.5V DC |
| Output Signal |
I2C ,UART (0~3V) ,analog voltage |
| Lifespan |
>2 years (in air) |
| Working Humidity Range |
0-99% RH (non-condensing) |
| Working Temperature Range (°C) |
-20°C ~ +50°C |
| Product Dimensions |
32mm x 27mm/1.26 x 1.06 inch |
| Response Time ( μS) |
<5S |
| Mounting Holes Diameter (mm) |
inner diameter 3.1mm(0.12 inch)/outer diameter 6mm(0.24 inch) |
Out of stock
Out of stock
| Gas Detection |
Carbon Dioxide (CO2) |
|---|---|
| Operating Voltage |
4.5 ~ 5.5V DC |
| Average Current |
<85mA |
| Output |
UART |
| Measuring Range |
0 ~ 50000ppm |
| Accuracy |
± (50ppm + 5% reading) |
| Preheating Time |
3min |
| Response Time |
T90 < 30s |
| Operating Temperature |
0 ~ 50 ℃ |
| Operating Humidity |
0 ~ 95% RH (no condensation) |
| Service Life |
>5 years |
Out of stock
Out of stock
| Model No. |
TGS2602-B00 |
|---|---|
| Heater Voltage |
5.0±0.2V DC |
| Circuit Voltage |
5.0±0.2V DC |
| Heater power consumption |
280mW (typical) |
| Heater Current |
56±5mA |
| Sensing Principle |
MOS type |
| Heater Resistance |
approx 59Ω at room temp. (typical) |
| Load Resistance |
variable 0.45kΩ min |
| Sensor Resistance |
10kΩ ~ 100kΩ in air |
| Standard Package |
TO-5 metal can |
| Target Gases |
Air contaminants (VOCs ,ammonia ,H2S ,etc.) |
| Test Gas Conditions |
normal air at 20±2˚C ,65±5%RH |
Out of stock
| Model No. |
TGS2611-C00 |
|---|---|
| Sensing Principle |
MOS type |
| Standard Package |
TO-5 metal can |
| Target Gases |
Methane ,Natural Gas |
| Heater Voltage |
5.0±0.2V DC |
| Circuit Voltage |
5.0±0.2V DC |
| Load Resistance |
variable 0.45kΩ min. |
| Heater Resistance |
approx 59Ω at room temp. |
| Heater Current |
56±5mA |
| Heater power consumption |
280mW±25mW |
| Sensor Resistance |
0.68~6.8kΩ in 5000ppm methane |
| Test Gas Conditions |
Methane in air at 20±2˚C ,65±5%RH |