When there is a fire a lot of gas particles are produced. The sensor detects these and turns the electricity supply on. It can be used to detect the presence of carbon monoxide gas (CO). Smoke alarms or gas alarms work on the same principle.
MP-2 model with advanced planar construction is comprised of heater and metal oxide
semiconductor material of subminiature Al2O3 ceramic plate, fetch out electrode down-lead,
encapsulation in metal base and cap. When the target gas exists , the sensor’s conductivity is
more higher along with the gas concentration rising. Please use simple electro circuit, convert
change of conductivity to correspond output signal of gas concentration.
Applications:
Domestic smoke leakage alarm, industrial smoke gas alarm and portable smoke detector.
1 x Winsen MP-2 Smoke Gas Sensor
Only logged in customers who have purchased this product may leave a review.
Shipping and Delivery Policy
1. Shipping Process:
2. Shipping Charges:
3. Order Tracking:
4. Delivery Address:
5. Delivery Issues:
6. No Return Policy for Opened/Soldered Products:
7. Refund Policy:
Out of stock
Out of stock
| Gas Detection |
Carbon Dioxide (CO2) |
|---|---|
| Operating Voltage |
4.5 ~ 5.5V DC |
| Average Current |
<85mA |
| Output |
UART |
| Measuring Range |
0 ~ 50000ppm |
| Accuracy |
± (50ppm + 5% reading) |
| Preheating Time |
3min |
| Response Time |
T90 < 30s |
| Operating Temperature |
0 ~ 50 ℃ |
| Operating Humidity |
0 ~ 95% RH (no condensation) |
| Service Life |
>5 years |
Out of stock
Out of stock
Out of stock
| Heater voltage |
5.0±0.2V DC |
|---|---|
| Circuit Voltage |
5.0±0.2V DC |
| Heater Current |
56±5mA |
| Minimum impedance between Pin#2,3 and GND |
2.5MΩ |
| Operating conditions |
0Ëš~40ËšC ,30~95%RH |
| Temperature differential between inside and outside detector casing |
≤10˚C max. (see NOTE 1) |
| Test gas conditions |
1250±100ppm iso-butane in air at 20˚±2˚C ,65±5%RH |
| Circuit conditions |
VH=5.0±0.05V DC VC=5.0±0.05V DC |
Out of stock
| Product Name |
Figaro TGS 2600 Air Quality Sensor |
|---|---|
| Input Voltage (V) |
5.0±0.2V AC/DC |
| Load Resistance |
variable 0.45kΩ min. |
| Heater Resistance (Ω) |
approx 83Ω at room temp. (typical) |
| Heater current (mA) |
42±4mA |
| Heater power consumption (mW) |
210 |
| Sensor Resistance (kΩ) |
10kΩ ~ 90kΩ in air |
| Sensitivity (change ratio of Rs) |
0.3~0.6 Rs (10ppm of H2)/ Rs air |
Out of stock
| Model No. |
TGS2610-C00 |
|---|---|
| Heater Current |
56±5mA |
| Heater Resistance |
approx 59Ω at room temp. |
| Heater Voltage |
5.0±0.2V DC |
| Load Resistance |
variable 0.45kΩ min |
| Sensing Principle |
MOS type |
| Circuit Voltage |
5.0±0.2V DC |
| Sensor Resistance |
1.0~10.0kΩ in 1800ppm iso-butane |
| Standard Package |
TO-5 metal can |
| Target Gases |
Butane ,LP gas |
| Test Gas Conditions |
iso-butane in air at 20±2˚C ,65±5%RH |
| Heater power consumption |
280mW VH = 5.0V DC |
Out of stock