Winsen ZE03-H2S GAS Sensor Module

SKU: 1021480
Out of stock

6,999.00

Add to Wishlist
Add to Wishlist
  1. Model No: ZE03
  2. Target Gas: CO, SO2, NH3, H2S, O2
  3. Measurement Range: C0: 0~1000 ppm, SO2: 0~20 ppm, NH3: 0~100 ppm.
  4. Working Voltage DC:3.7V~9V
  5. Working Current:< 5 mA
  6. Output Data: UART Output (3V electrical level)
Out of stock

Did you like this product? Add to favorites now and follow the product.

Add to Wishlist
Add to Wishlist

Description

This is a Winsen ZE03-H2S GAS Sensor Module.ZE03 is a general-purpose and high-performance electrochemical module. It uses three electrodes, an electrochemical gas sensor, and a high-performance microprocessor. By installing the different gas sensors, the module could detect relevant gas. It is with a built-in temperature sensor to make temperature compensation, which makes it could detect the gas concentration accurately. It has the digital output and analog voltage output at the same time which facilities the usage and calibration and shortens the development period. It is a combination of mature electrochemical detection principles and sophisticated circuit design, to meet customers’ different detection needs.

Winsen ZE03-H2S GAS Sensor Module

Applications:

Portable and fixed gas detector, various gas detection equipment, and situation.


Features:

  1. High sensitivity & resolution
  2. Low power consumption
  3. UART and analog voltage output
  4. Good stability and excellent anti-interference ability

Package Includes:

1 x Winsen ZE03-H2S GAS Sensor Module

Additional information

Model

ZE03

Target Gas

CO, SO2, NH3, H2S, O2

Working Voltage(V)

3.7V~9V

Working Current(mA)

<5mA

Working Temperature Range (°C)

0 to 50

Working Humidity Range

20%-90% RH

Height (mm)

24.5

Weight (gm)

13

Quick Comparison

SettingsWinsen ZE03-H2S GAS Sensor Module removeDFRobot Air Quality Monitor (PM 2.5, Formaldehyde, Temperature & Humidity Sensor) removeFigaro TGS2602 Air Quality / VOC Sensor removeFigaro TGS2610-C00 LP Gas Sensor removeDFRobot Indoor ENS160 Air Quality Sensor – I2C removeFigaro TGS6812-D00 Hydrogen/Methane/LPG Sensor remove
NameWinsen ZE03-H2S GAS Sensor Module removeDFRobot Air Quality Monitor (PM 2.5, Formaldehyde, Temperature & Humidity Sensor) removeFigaro TGS2602 Air Quality / VOC Sensor removeFigaro TGS2610-C00 LP Gas Sensor removeDFRobot Indoor ENS160 Air Quality Sensor – I2C removeFigaro TGS6812-D00 Hydrogen/Methane/LPG Sensor remove
Image
SKU102148014472631468924146892513978431468931
Rating
Price6,999.004,599.001,299.00399.003,799.002,099.00
Stock
Out of stock
In Stock
In Stock
In Stock
In Stock
In Stock
AvailabilityOut of stockIn StockIn StockIn StockIn StockIn Stock
Add to cart

Read more

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
  1. Model No: ZE03
  2. Target Gas: CO, SO2, NH3, H2S, O2
  3. Measurement Range: C0: 0~1000 ppm, SO2: 0~20 ppm, NH3: 0~100 ppm.
  4. Working Voltage DC:3.7V~9V
  5. Working Current:< 5 mA
  6. Output Data: UART Output (3V electrical level)
  1. Product: DFRobot Air Quality Monitor (PM 2.5, Formaldehyde, Temperature & Humidity Sensor)
  2. DC Supply Voltage:  Typ: 5V Min: 4.5V Max: 5.5V
  3. Working Current: ≤100mA
  4. Single Response Time: <1s
  5. Particle Counting Efficiency: 50%@0.3μm, 98%@>=0.5μm
  1. Product: Figaro TGS2602 Air Quality / VOC Sensor
  2. Heater Voltage: 5.0±0.2V DC
  3. Circuit Voltage:  5.0±0.2V DC
  4. Heater power consumption: 280mW (typical)
  5. Heater Current: 56±5mA
  1. Product: Figaro TGS2610-C00 LP Gas Sensor
  2. Heater Current: 56±5mA
  3. Heater Resistance: approx 59Ω at room temp
  4. Heater Voltage: 5.0±0.2V DC
  5. Load Resistance: variable 0.45 kΩ min.
  1. Product: DFRobot Indoor ENS160 Air Quality Sensor – I2C
  2. Supply Voltage: 3.3V~5V
  3. Operating Current: 29mA
  4. Preheat Time: <3 minutes
  5. Communication Mode: I2C
  6. I2C Address: 0x53
  1. Model No.: TGS6812-D00
  2. Heater Current: 175mA (typical)
  3. Heater power consumption:
  4. Target Gases: Hydrogen, methane, iso-butane
Content

This is a Winsen ZE03-H2S GAS Sensor Module.ZE03 is a general-purpose and high-performance electrochemical module. It uses three electrodes, an electrochemical gas sensor, and a high-performance microprocessor. By installing the different gas sensors, the module could detect relevant gas. It is with a built-in temperature sensor to make temperature compensation, which makes it could detect the gas concentration accurately. It has the digital output and analog voltage output at the same time which facilities the usage and calibration and shortens the development period. It is a combination of mature electrochemical detection principles and sophisticated circuit design, to meet customers’ different detection needs.

Winsen ZE03-H2S GAS Sensor Module

Applications:

Portable and fixed gas detector, various gas detection equipment, and situation.


Features:

  1. High sensitivity & resolution
  2. Low power consumption
  3. UART and analog voltage output
  4. Good stability and excellent anti-interference ability

Package Includes:

1 x Winsen ZE03-H2S GAS Sensor Module

Healthy living starts with healthy air! As the most basic part of life, air is attracting more and more attention these years, for example, PM2.5, smog, etc. Keeping an eye on the quality of the air we breathe is becoming quite important.

This Air Quality Monitor introduced by DFRobot provides you with the measurements of PM10, PM2.5, and PM1.0 as well as temperature and humidity. It works well with devices like Arduino, STM32.Based on the principle of laser scattering, this sensor continuously collects and calculates the number of suspended particles of various sizes in the air per unit volume, which is particle concentration distribution, and then converts to mass concentration. At the same time, a temperature & humidity integrated sensing chip is embedded in the module for accurately detecting the temperature and humidity.

In a word, this air quality sensor combines the particle concentration value, temperature, and humidity monitoring functions onto one module, and outputs the relevant data frames via UART. It can be embedded in various instruments and equipment related to air quality monitoring and environmental air improvement to provide timely and accurate environmental parameters.


Features:

  1. Laser scattering principle, accurate measurement
  2. Zero false alarm rate
  3. Real-time response and support continuous acquisition
  4. Minimum recognizable particle size 0.3μm
  5. Brand-new patented structure, six-sided all-around shielding, stronger anti-interference performance
  6. The direction of the air inlet and outlet is optional, and wider application ranges
  7. Real-time output temperature and humidity data

Package Includes:

1 x DFRobot Air Quality Monitor (PM 2.5, Formaldehyde, Temperature & Humidity Sensor)

The sensing element comprises a metal oxide semiconductor layer formed on the alumina substrate of a sensing chip together with an integrated heater. In the presence of detectable gas, sensor conductivity increases depending on gas concentration in the air. A simple electrical circuit can convert the change in conductivity to an output signal which corresponds to the gas concentration. The TGS2602 has high sensitivity to low concentrations of odorous gases such as ammonia and H2S generated from waste materials in office and home
environments. The sensor also has a high sensitivity to low concentrations of VOCs such as toluene emitted from wood finishing and construction products.

Note: For more technical details go through Datasheet in the attachment section 


Features:

  1. High sensitivity to VOCs and odorous gases
  2. Low power consumption
  3.  High sensitivity to gaseous air contaminants
  4. Long life
  5.  It uses a simple electrical circuit
  6.  Small size

Package Includes:

1 x Figaro TGS2602 Air Quality / VOC Sensor

TGS2610-C00 is a semiconductor type gas sensor which combines very high sensitivity to LP gas with low power consumption and long life. Due to miniaturization of its sensing chip, TGS2610-C00 requires a heater current of
only 56 mA and the device is housed in a standard TO-5 package. TGS2610-C00 possesses small size and quick gas response, making it suitable for gas leakage checkers. The TGS2610-C00 is able to satisfy the requirements of performance standards such as UL1484 and EN50194.

Note: For more technical details go through Datasheet in the attachment section 


Features:

  1. Quick response
  2.  Low power consumption
  3.  Long life and low cost
  4.  Uses simple electrical circuit

Package Includes:

1 x Figaro TGS2610-C00 LP Gas Sensor

This ENS160 Air Quality Sensor (I2C), based on ScioSense’s new ENS160 sensor chip, is specifically designed for indoor air quality monitoring and offers detection of multiple IAQ data (TVOC, eCO2, AQI). The combination of the innovative TrueVOC™ technology and the metal oxide (MOX) technology brings this sensor superior accuracy, fast response, anti-interference, etc.

With intelligent on-chip algorithms, the ENS160 can directly output rich and easy-to-understand environmental data. Preheat the sensor 3 minutes before use to obtain accurate data more quickly. What’s more, the built-in automatic baseline correction algorithm ensures the long-term stability of the sensor.


Features:

  1. The probe shape makes installation easier
  2. Multiple IAQ outputs (TVOC, eCO2, AQI), various environmental data
  3. Less than 3 minutes warm-up time, get data faster
  4. Built-in algorithm, more accurate output
  5. Automatic baseline correction, more stable for long-term use

Specifications:

  1. Supply Voltage: 3.3V~5V
  2. Operating Current: 29mA
  3. Preheat Time: <3 minutes
  4. Communication Mode: I2C
  5. I2C Address: 0x53
  6. Operating Temperature: -10℃~80℃
  7. Operating Humidity: 5%RH~95%RH (Non-condensing)
  8. eCO2 Detection Range: 400ppm~65000ppm
  9. TVOC Detection Range: 0ppb~65000ppb
  10. Cable Length: 1m

Package Includes:

1 x DFRobot Indoor ENS160 Air Quality Sensor – I2C

The TGS6812-D00 catalytic-type gas sensor can detect levels of hydrogen up to 100%LEL. This sensor features high accuracy, good durability and stability, quick response, and linear output. This sensor can detect not only hydrogen but also methane and LP gas, thus making it an excellent solution for monitoring gas leakage from stationary fuel cell systems which transform combustible gases into hydrogen. As the sensor possesses a proprietary filter material inside its sensor cap, its cross-sensitivity to organic vapors is small. In addition, TGS6812-D00 is durable against silicone compounds in harsh environments.

N0te: For more technical details go through Datasheet in the Attachment sections

Applications:
Hydrogen and combustible gas leak
detectors for fuel cells


Features:

  1. Linear output
  2.  Long life
  3.  Small sensitivity to organic vapors
  4.  Sensitive to hydrogen, methane, and
    LP gas

Package Includes:

1 x Figaro TGS6812-D00 Hydrogen/Methane/LPG Sensor

Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Model

ZE03

Target Gas

CO, SO2, NH3, H2S, O2

Working Voltage(V)

3.7V~9V

Working Current(mA)

<5mA

Working Temperature Range (°C)

0 to 50

Working Humidity Range

20%-90% RH

Height (mm)

24.5

Weight (gm)

13

Particle Measurement Range

0.3~1.0μm; 1.0~2.5μm; 2.5~10μm

Particle Counting Efficiency

50%@0.3μm, 98%@>=0.5μm

Resolution of Particle Mass Concentration

1μg/mᶟ

Temperature Measurement Range

0~99℃

Temperature Measurement Resolution

0.1℃

Humidity Measurement Range

0~99%

Humidity Measurement Resolution

0.1%

Humidity Measurement Accuracy

±2%

Single Response Time

<1s

Comprehensive Response Time

≤10s

DC Supply Voltage

Typ: 5V Min: 4.5V Max: 5.5V

Working Current

≤100mA

Standby Current

≤200mA

Data Interface Level

L<0.8V, H>2.7V, maximum level voltage 3.3V

Working Temperature Range

10~50℃

Working Humidity Range

0~99%

Storage Temperature Range

40~80℃

Model No.

TGS2602-B00

Heater Voltage

5.0±0.2V DC

Circuit Voltage

5.0±0.2V DC

Heater power consumption

280mW (typical)

Heater Current

56±5mA

Sensing Principle

MOS type

Heater Resistance

approx 59Ω at room temp. (typical)

Load Resistance

variable 0.45kΩ min

Sensor Resistance

10kΩ ~ 100kΩ in air

Standard Package

TO-5 metal can

Target Gases

Air contaminants (VOCs, ammonia, H2S, etc.)

Test Gas Conditions

normal air at 20±2˚C, 65±5%RH

Model No.

TGS2610-C00

Heater Current

56±5mA

Heater Resistance

approx 59Ω at room temp.

Heater Voltage

5.0±0.2V DC

Load Resistance

variable 0.45kΩ min

Sensing Principle

MOS type

Circuit Voltage

5.0±0.2V DC

Sensor Resistance

1.0~10.0kΩ in 1800ppm iso-butane

Standard Package

TO-5 metal can

Target Gases

Butane, LP gas

Test Gas Conditions

iso-butane in air at 20±2˚C, 65±5%RH

Heater power consumption

280mW VH = 5.0V DC

Model No.

TGS6812-D00

Heater Current

175mA (typical)

Heater power consumption

525mW (typical)

Target Gases

Hydrogen, methane, iso-butane

Test Gas Conditions

Hydrogen/methane/iso-butane in air at 20±2˚C, 65±5%RH

Zero offset

-15 ~ +55mV