Fast Shipping
Get the Priority Shipping on Prepaid Orders
Prepaid Orders
-
Normal Shipping
Get Normal Delivery (Surface) with Cash On Delivery
COD Orders
₹14,789.95 (Including tax)
Discount per Bulk Quantity
Quantity | Discount | Price |
---|---|---|
5 - 10 | 5% | ₹14,050.44 (Including tax) |
11 - 20 | 8% | ₹13,606.74 (Including tax) |
21 - 40 | 10% | ₹13,310.95 (Including tax) |
41 - 100 | 12% | ₹13,015.15 (Including tax) |
Out of stock
No worries! Enter your email, and we'll let you know as soon as it's back in stock.
Get the Priority Shipping on Prepaid Orders
Prepaid Orders
Get Normal Delivery (Surface) with Cash On Delivery
COD Orders
In the ever-increasing need and awareness for health and safety, water has become a focus point for proper disinfection treatment as aftereffects of industrialization can become a danger for contamination of water via direct contact. Water is a critical control point of contact where proper treatment can greatly reduce these microbes, thereby reducing the chances of illness and pollution.
While traditional ORP meters are hard to get or use, this Analog ORP Meter is a highly compact ORP monitoring system that fits into your Arduino. This design configuration allows the user to accurately monitor ORP without having to add any additional circuitry or components to your design. Communication with the Analog ORP Meter is done using only simple wiring and programming.
1 x ORP probe (BNC connector)
1 x ORP probe circuit board
1 x Analog cable
Model |
DFRobot Gravity Lab Grade Analog ORP Sensor |
---|---|
PH2.0 |
Interface(3 foot patch) |
Module Power |
+5.00V |
Working Temperature Range (°C) |
5-70℃ |
Product Dimensions |
40mm X 27mm(1.57″x1.06″) |
Measuring Range |
– 2000mV—2000mV |
Accuracy |
±10mv (25 ℃) |
Response Time ( μS) |
≤20sec |
Only logged in customers who have purchased this product may leave a review.
Shipping and Delivery Policy
1. Shipping Process:
2. Shipping Charges:
3. Order Tracking:
4. Delivery Address:
5. Delivery Issues:
6. No Return Policy for Opened/Soldered Products:
7. Refund Policy:
Out of stock
Particle Measurement Range |
0.3~1.0μm; 1.0~2.5μm; 2.5~10μm |
---|---|
Particle Counting Efficiency |
50%@0.3μm ,98%@>=0.5μm |
Resolution of Particle Mass Concentration |
1μg/mᶟ |
Temperature Measurement Range |
0~99℃ |
Temperature Measurement Resolution |
0.1℃ |
Humidity Measurement Range |
0~99% |
Humidity Measurement Resolution |
0.1% |
Humidity Measurement Accuracy |
±2% |
Single Response Time |
<1s |
Comprehensive Response Time |
≤10s |
DC Supply Voltage |
Typ: 5V Min: 4.5V Max: 5.5V |
Working Current |
≤100mA |
Standby Current |
≤200mA |
Data Interface Level |
L<0.8V ,H>2.7V ,maximum level voltage 3.3V |
Working Temperature Range |
10~50℃ |
Working Humidity Range |
0~99% |
Storage Temperature Range |
40~80℃ |
Out of stock
Detection Gas |
Oxygen concentration |
---|---|
Detection range |
0~100% |
Working Pressure Range |
0.5~2.0Bar |
Working Voltage |
3.3~5.5V DC |
Output Signal |
I2C ,UART (0~3V) ,analog voltage |
Lifespan |
>2 years (in air) |
Working Humidity Range |
0-99% RH (non-condensing) |
Working Temperature Range (°C) |
-20°C ~ +50°C |
Product Dimensions |
32mm x 27mm/1.26 x 1.06 inch |
Response Time ( μS) |
<5S |
Mounting Holes Diameter (mm) |
inner diameter 3.1mm(0.12 inch)/outer diameter 6mm(0.24 inch) |
Out of stock
Out of stock
Out of stock
Heater voltage |
5.0±0.2V DC |
---|---|
Circuit Voltage |
5.0±0.2V DC |
Heater Current |
56±5mA |
Minimum impedance between Pin#2,3 and GND |
2.5MΩ |
Operating conditions |
0Ëš~40ËšC ,30~95%RH |
Temperature differential between inside and outside detector casing |
≤10˚C max. (see NOTE 1) |
Test gas conditions |
1250±100ppm iso-butane in air at 20˚±2˚C ,65±5%RH |
Circuit conditions |
VH=5.0±0.05V DC VC=5.0±0.05V DC |
Out of stock
Out of stock
Model No. |
TGS2610-C00 |
---|---|
Heater Current |
56±5mA |
Heater Resistance |
approx 59Ω at room temp. |
Heater Voltage |
5.0±0.2V DC |
Load Resistance |
variable 0.45kΩ min |
Sensing Principle |
MOS type |
Circuit Voltage |
5.0±0.2V DC |
Sensor Resistance |
1.0~10.0kΩ in 1800ppm iso-butane |
Standard Package |
TO-5 metal can |
Target Gases |
Butane ,LP gas |
Test Gas Conditions |
iso-butane in air at 20±2˚C ,65±5%RH |
Heater power consumption |
280mW VH = 5.0V DC |
Out of stock
No account yet?
Create an Account
Reviews
Clear filtersThere are no reviews yet.