The greenhouse Effect” is melting the Earth’s ice core every minute and creating dangerous icebergs. By knowing the exact concentration of CO2(Carbon Dioxide), we can do something to reduce the CO2 and to protect our Earth. Here is the Arduino-based CO2 sensor designed by DFRobot’s lovely engineer. This is the first CO2 sensor in the Arduino market. Â The output voltage of the module falls as the concentration of CO2 increases. The potentiometer onboard is designed to set the threshold of voltage. As long as the CO2 concentration is high enough (the voltage is lower than the threshold), Â a digital signal (ON/OFF) will be released.
It has an MG-811 sensor module which is highly sensitive to CO2 and less sensitive to alcohol and CO, low humidity & temperature dependency. The onboard heating circuit brings the best temperature for the sensor to function. Internal power boosting to 6V for heating sensor best performance. This sensor has an onboard conditioning circuit for amplifying the output signal.
1 x DFRobot Gravity Analog CO2 Gas Sensor For Arduino (MG-811 Sensor)
Only logged in customers who have purchased this product may leave a review.
Shipping and Delivery Policy
1. Shipping Process:
2. Shipping Charges:
3. Order Tracking:
4. Delivery Address:
5. Delivery Issues:
6. No Return Policy for Opened/Soldered Products:
7. Refund Policy:
Out of stock
| Detection Gas |
Oxygen concentration |
|---|---|
| Detection range |
0~100% |
| Working Pressure Range |
0.5~2.0Bar |
| Working Voltage |
3.3~5.5V DC |
| Output Signal |
I2C ,UART (0~3V) ,analog voltage |
| Lifespan |
>2 years (in air) |
| Working Humidity Range |
0-99% RH (non-condensing) |
| Working Temperature Range (°C) |
-20°C ~ +50°C |
| Product Dimensions |
32mm x 27mm/1.26 x 1.06 inch |
| Response Time ( μS) |
<5S |
| Mounting Holes Diameter (mm) |
inner diameter 3.1mm(0.12 inch)/outer diameter 6mm(0.24 inch) |
Out of stock
| Detection Gas |
Hydrogen (H2) |
|---|---|
| Detection range |
0~1000ppm |
| Working Voltage |
3.3~5.5V DC |
| Working Current |
<5mA |
| Output Signal |
I2C ,UART (0~3V) ,analog voltage |
| Working Temperature |
-20~50℃ |
| Working Humidity |
15~90%RH (non-condensing) |
| Storage Temperature |
-20~50℃ |
| Communication Protocol |
I2C ,UART and analog |
| Compatibility |
Arduino ,ESP32 ,Raspberry pi |
| Storage Humidity |
15~90%RH (non-condensing) |
| Lifespan |
>2 years (in the air) |
| Adapter Plate Size |
37 x 32mm |
Out of stock
Out of stock
| Model No. |
TGS2602-B00 |
|---|---|
| Heater Voltage |
5.0±0.2V DC |
| Circuit Voltage |
5.0±0.2V DC |
| Heater power consumption |
280mW (typical) |
| Heater Current |
56±5mA |
| Sensing Principle |
MOS type |
| Heater Resistance |
approx 59Ω at room temp. (typical) |
| Load Resistance |
variable 0.45kΩ min |
| Sensor Resistance |
10kΩ ~ 100kΩ in air |
| Standard Package |
TO-5 metal can |
| Target Gases |
Air contaminants (VOCs ,ammonia ,H2S ,etc.) |
| Test Gas Conditions |
normal air at 20±2˚C ,65±5%RH |
Out of stock
| Model No. |
TGS2610-C00 |
|---|---|
| Heater Current |
56±5mA |
| Heater Resistance |
approx 59Ω at room temp. |
| Heater Voltage |
5.0±0.2V DC |
| Load Resistance |
variable 0.45kΩ min |
| Sensing Principle |
MOS type |
| Circuit Voltage |
5.0±0.2V DC |
| Sensor Resistance |
1.0~10.0kΩ in 1800ppm iso-butane |
| Standard Package |
TO-5 metal can |
| Target Gases |
Butane ,LP gas |
| Test Gas Conditions |
iso-butane in air at 20±2˚C ,65±5%RH |
| Heater power consumption |
280mW VH = 5.0V DC |
Out of stock
| Model number |
TGS5141-P00 |
|---|---|
| Output current in CO |
1.2~3.2nA/ppm |
| Target Gases |
Carbon monoxide |
| Typical detection range |
0 ~ 5 ,000ppm |
| Baseline offset(*1) |
<±10ppm equivalent |
| Operating temperature |
10ËšC ~ +50ËšC (continuous) -20ËšC ~ +60ËšC (intermittent) |
| Operating humidity |
10 ~ 95%RH (no condensation) |
| Response time (T90) |
within 60 seconds |
| Storage conditions |
-10ËšC ~ +50ËšC (continuous) -20ËšC ~ +60ËšC (intermittent |
| Standard test conditions |
20±2˚C ,40±10%RH |
| Weight |
approx. 2.5g |