Sort by
DFRobot Gravity: O2 Sensor (Calibrated) – I2C & UART
Out of stock
DFRobot Gravity: PM2.5 Air Quality Sensor
Out of stock
Model |
PM2.5 |
---|---|
Operating Voltage(V) |
5.0 |
Maximum Working Current(mA) |
100 |
Standby Current(mA) |
≤2 |
Standard Volume(L) |
0.1 |
Single Response Time(s) |
<1 |
Particle Measurement Range |
0.3 ~ 1.0μm 1.0 ~ 2.5μm 2.5 ~ 10μm |
Comprehensive Response Time(s) |
≤10 |
Working Temperature Range (°C) |
-10~+60 |
Opt. Relative Humidity(RH) |
0~95% |
Dimensions in mm (LxWxH) |
67x40x14 |
Weight (gm) |
30 |
DFRobot Indoor ENS160 Air Quality Sensor – I2C
Out of stock
Figaro CMM 5042 Embedded Module for Carbon Monoxide
Out of stock
Figaro LPM2610-D09 Butane and Propane Gas Sensor Module
Out of stock
Heater voltage |
5.0±0.2V DC |
---|---|
Circuit Voltage |
5.0±0.2V DC |
Heater Current |
56±5mA |
Minimum impedance between Pin#2,3 and GND |
2.5MΩ |
Operating conditions |
0Ëš~40ËšC ,30~95%RH |
Temperature differential between inside and outside detector casing |
≤10˚C max. (see NOTE 1) |
Test gas conditions |
1250±100ppm iso-butane in air at 20˚±2˚C ,65±5%RH |
Circuit conditions |
VH=5.0±0.05V DC VC=5.0±0.05V DC |
Figaro NGM2611-E13 Methane Sensor Module factory calibrated
Out of stock
Figaro TGS 2600 Air Quality Sensor
Out of stock
Product Name |
Figaro TGS 2600 Air Quality Sensor |
---|---|
Input Voltage (V) |
5.0±0.2V AC/DC |
Load Resistance |
variable 0.45kΩ min. |
Heater Resistance (Ω) |
approx 83Ω at room temp. (typical) |
Heater current (mA) |
42±4mA |
Heater power consumption (mW) |
210 |
Sensor Resistance (kΩ) |
10kΩ ~ 90kΩ in air |
Sensitivity (change ratio of Rs) |
0.3~0.6 Rs (10ppm of H2)/ Rs air |
Figaro TGS2602 Air Quality / VOC Sensor
Out of stock
Model No. |
TGS2602-B00 |
---|---|
Heater Voltage |
5.0±0.2V DC |
Circuit Voltage |
5.0±0.2V DC |
Heater power consumption |
280mW (typical) |
Heater Current |
56±5mA |
Sensing Principle |
MOS type |
Heater Resistance |
approx 59Ω at room temp. (typical) |
Load Resistance |
variable 0.45kΩ min |
Sensor Resistance |
10kΩ ~ 100kΩ in air |
Standard Package |
TO-5 metal can |
Target Gases |
Air contaminants (VOCs ,ammonia ,H2S ,etc.) |
Test Gas Conditions |
normal air at 20±2˚C ,65±5%RH |
Figaro TGS2610-C00 LP Gas Sensor
Out of stock
Model No. |
TGS2610-C00 |
---|---|
Heater Current |
56±5mA |
Heater Resistance |
approx 59Ω at room temp. |
Heater Voltage |
5.0±0.2V DC |
Load Resistance |
variable 0.45kΩ min |
Sensing Principle |
MOS type |
Circuit Voltage |
5.0±0.2V DC |
Sensor Resistance |
1.0~10.0kΩ in 1800ppm iso-butane |
Standard Package |
TO-5 metal can |
Target Gases |
Butane ,LP gas |
Test Gas Conditions |
iso-butane in air at 20±2˚C ,65±5%RH |
Heater power consumption |
280mW VH = 5.0V DC |
Figaro TGS2611-C00 Methane Sensor
Out of stock
Model No. |
TGS2611-C00 |
---|---|
Sensing Principle |
MOS type |
Standard Package |
TO-5 metal can |
Target Gases |
Methane ,Natural Gas |
Heater Voltage |
5.0±0.2V DC |
Circuit Voltage |
5.0±0.2V DC |
Load Resistance |
variable 0.45kΩ min. |
Heater Resistance |
approx 59Ω at room temp. |
Heater Current |
56±5mA |
Heater power consumption |
280mW±25mW |
Sensor Resistance |
0.68~6.8kΩ in 5000ppm methane |
Test Gas Conditions |
Methane in air at 20±2˚C ,65±5%RH |
Figaro TGS3870 Methane/Carbon Monoxide Sensor
Out of stock
Model No. |
TGS3870-F00 |
---|---|
Circuit Voltage |
5.0±0.2V DC pulse |
Load Resistance |
variable (>0.75kΩ) |
Sensing Principle |
MOS type |
Sensor Resistance |
0.3kΩ~5.0kΩ in 3000ppm methane 2kΩ~40kΩ in 200ppm CO |
Standard Package |
Plastic base and metal can |
Target Gases |
Methane and Carbon Monoxide |
Test Gas Conditions |
Target gas in air at 20±2˚C ,65±5%RH |
Figaro TGS5042-A00 Carbon Monoxide Sensor Industrial safety
Out of stock
Model No. |
TGS5042-A00 |
---|---|
Target Gases |
Carbon monoxide |
Typical detection range |
0 ~ 10 ,000ppm |
Output current in CO |
1.2~2.4nA/ppm |
Baseline offset(*1) |
<±10ppm equivalent |
Operating & storage temperature (*2,*3) |
-5ËšC ~ +55ËšC |
Operating humidity |
5 ~ 99%RH (no condensation) |
Response time (T90) |
within 60 seconds |
Standard test conditions |
20±2˚C ,40±10%RH |