Fast Shipping
Get the Priority Shipping on Prepaid Orders
Prepaid Orders
-
Normal Shipping
Get Normal Delivery (Surface) with Cash On Delivery
COD Orders
₹1,898.45 (Including tax)
Discount per Bulk Quantity
Quantity | Discount | Price |
---|---|---|
5 - 10 | 5% | ₹1,803.53 (Including tax) |
11 - 20 | 8% | ₹1,746.56 (Including tax) |
21 - 40 | 10% | ₹1,708.61 (Including tax) |
41 - 100 | 12% | ₹1,670.63 (Including tax) |
Out of stock
No worries! Enter your email, and we'll let you know as soon as it's back in stock.
Get the Priority Shipping on Prepaid Orders
Prepaid Orders
Get Normal Delivery (Surface) with Cash On Delivery
COD Orders
The LPM2610 is a pre-calibrated module for LP gas alarms which is precisely calibrated in Figaro’s humidity and temperature-controlled facility. The module uses TGS2610-D00 which incorporates a filter to eliminate the influence of interference gases such as alcohol, resulting in highly selective response to LP gas. The most important process in manufacturing reliable residential gas alarms is adjusting the alarm point. Calibration is a complicated and time-consuming process that also requires a substantial investment in calibration equipment. By
eliminating the costly calibration process, this module enables users to easily and simply manufacture residential LP gas alarms. Figaro has taken the complexity out of designing a gas detector circuit by providing users with a temperature compensation circuit that combines a built-in thermistor and individually adjusted load resistor together with Figaro’s low-power LP gas sensor.
1 x Figaro LPM2610-D09 Butane and Propane Gas Sensor Module
Heater voltage |
5.0±0.2V DC |
---|---|
Circuit Voltage |
5.0±0.2V DC |
Heater Current |
56±5mA |
Minimum impedance between Pin#2,3 and GND |
2.5MΩ |
Operating conditions |
0Ëš~40ËšC ,30~95%RH |
Temperature differential between inside and outside detector casing |
≤10˚C max. (see NOTE 1) |
Test gas conditions |
1250±100ppm iso-butane in air at 20˚±2˚C ,65±5%RH |
Circuit conditions |
VH=5.0±0.05V DC VC=5.0±0.05V DC |
Only logged in customers who have purchased this product may leave a review.
Shipping and Delivery Policy
1. Shipping Process:
2. Shipping Charges:
3. Order Tracking:
4. Delivery Address:
5. Delivery Issues:
6. No Return Policy for Opened/Soldered Products:
7. Refund Policy:
Out of stock
Detection Gas |
Hydrogen (H2) |
---|---|
Detection range |
0~1000ppm |
Working Voltage |
3.3~5.5V DC |
Working Current |
<5mA |
Output Signal |
I2C ,UART (0~3V) ,analog voltage |
Working Temperature |
-20~50℃ |
Working Humidity |
15~90%RH (non-condensing) |
Storage Temperature |
-20~50℃ |
Communication Protocol |
I2C ,UART and analog |
Compatibility |
Arduino ,ESP32 ,Raspberry pi |
Storage Humidity |
15~90%RH (non-condensing) |
Lifespan |
>2 years (in the air) |
Adapter Plate Size |
37 x 32mm |
Out of stock
Model |
DFRobot Gravity NH3 Sensor |
---|---|
Detection Gas |
Ammonia (NH3) |
Detection range |
0~100ppm |
Working Voltage |
3.3~5.5V DC |
Working Current |
<5mA |
Output Signal |
I2C ,UART (0~3V) ,analog voltage |
Compatibility |
Arduino ,ESP32 ,Raspberry pi |
Lifespan |
>2 years (in the air) |
Working Humidity Range |
15~90%RH (non-condensing) |
Working Temperature Range (°C) |
-20~50℃ |
Product Dimensions |
37 x 32mm |
Out of stock
Gas Detection |
Carbon Dioxide (CO2) |
---|---|
Operating Voltage |
4.5 ~ 5.5V DC |
Average Current |
<85mA |
Output |
UART |
Measuring Range |
0 ~ 50000ppm |
Accuracy |
± (50ppm + 5% reading) |
Preheating Time |
3min |
Response Time |
T90 < 30s |
Operating Temperature |
0 ~ 50 ℃ |
Operating Humidity |
0 ~ 95% RH (no condensation) |
Service Life |
>5 years |
Out of stock
Out of stock
Product Name |
Figaro TGS 2600 Air Quality Sensor |
---|---|
Input Voltage (V) |
5.0±0.2V AC/DC |
Load Resistance |
variable 0.45kΩ min. |
Heater Resistance (Ω) |
approx 83Ω at room temp. (typical) |
Heater current (mA) |
42±4mA |
Heater power consumption (mW) |
210 |
Sensor Resistance (kΩ) |
10kΩ ~ 90kΩ in air |
Sensitivity (change ratio of Rs) |
0.3~0.6 Rs (10ppm of H2)/ Rs air |
Out of stock
Model No. |
TGS2610-C00 |
---|---|
Heater Current |
56±5mA |
Heater Resistance |
approx 59Ω at room temp. |
Heater Voltage |
5.0±0.2V DC |
Load Resistance |
variable 0.45kΩ min |
Sensing Principle |
MOS type |
Circuit Voltage |
5.0±0.2V DC |
Sensor Resistance |
1.0~10.0kΩ in 1800ppm iso-butane |
Standard Package |
TO-5 metal can |
Target Gases |
Butane ,LP gas |
Test Gas Conditions |
iso-butane in air at 20±2˚C ,65±5%RH |
Heater power consumption |
280mW VH = 5.0V DC |
Out of stock
Model number |
TGS5141-P00 |
---|---|
Output current in CO |
1.2~3.2nA/ppm |
Target Gases |
Carbon monoxide |
Typical detection range |
0 ~ 5 ,000ppm |
Baseline offset(*1) |
<±10ppm equivalent |
Operating temperature |
10ËšC ~ +50ËšC (continuous) -20ËšC ~ +60ËšC (intermittent) |
Operating humidity |
10 ~ 95%RH (no condensation) |
Response time (T90) |
within 60 seconds |
Storage conditions |
-10ËšC ~ +50ËšC (continuous) -20ËšC ~ +60ËšC (intermittent |
Standard test conditions |
20±2˚C ,40±10%RH |
Weight |
approx. 2.5g |
Out of stock
No account yet?
Create an Account
Reviews
Clear filtersThere are no reviews yet.