Waveshare Laser Sensor

SKU: 1219073
In Stock

899.00

  1. Effective distance: 0.8m(typ), 1.5m(max)
  2. Power: 2.5V ~ 5.0V
  3. Mounting holes size: 2.0mm
In Stock
Add to Wishlist
Add to Wishlist

Did you like this product? Add to favorites now and follow the product.

Add to Wishlist
Add to Wishlist

Description

Diffuse Reflection Laser Sensor Module Laser Ranging Module Obstacle Detection. Signal output indicator, Features boost circuit.Obstacle detection,Pipeline counter,Smart robot,Obstacle-avoiding car.

A laser sensor contains a transmitter and a receiver. In the transmitter, there is an oscillating tube can generate a shockwave in a frequency of 180KHz. After amplified by a transistor, the shockwave is applied to the laser tube for exciting. In the receiver, there is a receiving tube, matching to the oscillating tube, can receive the reflected light. Since the laser sensor adopts modulation processing technology, the receiving tube can only receive the reflected light in a same frequency, efficiently preventing from the visible light.

Application:

  1. Obstacle detection
  2. Pipeline counter
  3. Smart robot
  4. Obstacle-avoiding car

Features: 

  1. Boost circuit
  2. Signal output indicator

Specification:

  1. Effective distance: 0.8m(typ), 1.5m(max)
  2. Power: 2.5V ~ 5.0V
  3. Dimension: 47.7mm * 17.9mm
  4. Mounting holes size: 2.0mm

Package Includes:

1 x Laser Sensor
1 x 3-pin custom connector jumper wire

Additional information

Effective distance

0.8m(typ), 1.5m(max)

Voltage (V)

2.5V ~ 5.0V

Application

Obstacle detection, Obstacle-avoiding car

Interface

Digital Output, GND, VCC

Color

Blue

Outline dimension (mm)

47.7mm * 17.9mm

Mounting Hole Diameter (mm)

2.0mm

Quick Comparison

SettingsWaveshare Laser Sensor removeHydrogen sulfide sensor AHS3000 removeFigaro TGS6812-D00 Hydrogen/Methane/LPG Sensor removeDFRobot Gravity HF Sensor (Calibrated) – I2C, UART and analog removeFigaro TGS3870 Methane/Carbon Monoxide Sensor removeFigaro TGS5042-A00 Carbon Monoxide Sensor Industrial safety remove
NameWaveshare Laser Sensor removeHydrogen sulfide sensor AHS3000 removeFigaro TGS6812-D00 Hydrogen/Methane/LPG Sensor removeDFRobot Gravity HF Sensor (Calibrated) – I2C, UART and analog removeFigaro TGS3870 Methane/Carbon Monoxide Sensor removeFigaro TGS5042-A00 Carbon Monoxide Sensor Industrial safety remove
Image
SKU121907314436431468931135624514689281468929
Rating
Price899.001,099.002,099.0028,549.001,849.001,399.00
Stock
In Stock
In Stock
In Stock
In Stock
In Stock
In Stock
AvailabilityIn StockIn StockIn StockIn StockIn StockIn Stock
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
  1. Effective distance: 0.8m(typ), 1.5m(max)
  2. Power: 2.5V ~ 5.0V
  3. Mounting holes size: 2.0mm
  1. Product: Hydrogen sulfide sensor AHS3000
  2. Sensitivity (nA/ppm): 700±150
  3. Working Humidity Range: 15~90%RH (Non-Condensing)
  4. Working Pressure Range : 1atm±10%
  1. Model No.: TGS6812-D00
  2. Heater Current: 175mA (typical)
  3. Heater power consumption:
  4. Target Gases: Hydrogen, methane, iso-butane
  1. Brand: DFRobot
  2. Product: Gravity HF Sensor (Calibrated) – I2C & UART
  3. Detection Gas: Hydrogen fluoride (HF)
  4. Detection range: 0~10ppm
  5. Working Voltage: 3.3~5.5V DC
  6. Working Current: <5mA
  1. Product: Figaro TGS3870 Methane/Carbon Monoxide Sensor
  2. Circuit Voltage: 5.0±0.2V DC pulse
  3. Load Resistance: variable (>0.75kΩ)
  4. Sensing Principle: MOS type
  5. Sensor Resistance:  0.3kΩ~5.0kΩ in 3000ppm methane ,2kΩ~40kΩ in 200ppm CO

 

  1. Product: Figaro TGS5042-A00 Carbon Monoxide Sensor Industrial safety
  2. Target Gases: Carbon monoxide
  3. Typical detection range: 0 ~ 10,000ppm
  4. Output current in CO: 1.2~2.4nA/ppm
  5. Baseline offset(*1): <±10ppm equivalent
Content

Diffuse Reflection Laser Sensor Module Laser Ranging Module Obstacle Detection. Signal output indicator, Features boost circuit.Obstacle detection,Pipeline counter,Smart robot,Obstacle-avoiding car.

A laser sensor contains a transmitter and a receiver. In the transmitter, there is an oscillating tube can generate a shockwave in a frequency of 180KHz. After amplified by a transistor, the shockwave is applied to the laser tube for exciting. In the receiver, there is a receiving tube, matching to the oscillating tube, can receive the reflected light. Since the laser sensor adopts modulation processing technology, the receiving tube can only receive the reflected light in a same frequency, efficiently preventing from the visible light.

Application:

  1. Obstacle detection
  2. Pipeline counter
  3. Smart robot
  4. Obstacle-avoiding car

Features: 

  1. Boost circuit
  2. Signal output indicator

Specification:

  1. Effective distance: 0.8m(typ), 1.5m(max)
  2. Power: 2.5V ~ 5.0V
  3. Dimension: 47.7mm * 17.9mm
  4. Mounting holes size: 2.0mm

Package Includes:

1 x Laser Sensor
1 x 3-pin custom connector jumper wire

AHS3000 is a constant potential electrolytic sensor used to measure the concentration of hydrogen sulfide gas. It is small, high sensitivity, and fast response. It can be easily integrated into portable instruments, and can also replace the same type of hydrogen sulfide electrochemical sensor through pins.  Deliver high-quality products to customers stably and in batches.

Application

AHS3000 has a wide range of application scenarios, suitable for hydrogen sulfide detection in industrial sites and environmental protection fields, portable hydrogen sulfide detection instruments, fixed-point hydrogen sulfide detectors, etc.


Features:

  1. fast response
  2. good stability
  3. excellent long-term stability
  4. high linearity
  5. Small size, high sensitivity

Package Includes:

1 x Hydrogen sulfide sensor AHS3000

The TGS6812-D00 catalytic-type gas sensor can detect levels of hydrogen up to 100%LEL. This sensor features high accuracy, good durability and stability, quick response, and linear output. This sensor can detect not only hydrogen but also methane and LP gas, thus making it an excellent solution for monitoring gas leakage from stationary fuel cell systems which transform combustible gases into hydrogen. As the sensor possesses a proprietary filter material inside its sensor cap, its cross-sensitivity to organic vapors is small. In addition, TGS6812-D00 is durable against silicone compounds in harsh environments.

N0te: For more technical details go through Datasheet in the Attachment sections

Applications:
Hydrogen and combustible gas leak
detectors for fuel cells


Features:

  1. Linear output
  2.  Long life
  3.  Small sensitivity to organic vapors
  4.  Sensitive to hydrogen, methane, and
    LP gas

Package Includes:

1 x Figaro TGS6812-D00 Hydrogen/Methane/LPG Sensor

This is a sensor that detects hydrogen fluoride concentration and supports three output modes: analog, I2C, and UART. The probe has been calibrated at the factory, which can quickly and accurately measure the concentration of hydrogen fluoride in the environmentCan be widely used in the detection of hydrogen fluoride in industrial and environmental protection fields.

The probe adopts the electrochemical principle, has the characteristics of strong anti-interference ability, high stability, high sensitivity, etc., and the service life is as long as two years. The sensor has 32 modifiable I2C addresses, an integrated temperature compensation algorithm, and a threshold alarm function, It has good compatibility with mainstream main control devices such as Arduino, ESP32, and raspberry pie. The easy-to-use Gravity interface, coupled with our sample code, can quickly build a hydrogen fluoride concentration detector.DFRobot has introduced 12 gas detection sensors in this series, CO, 02, NH3, H2S, NO2, HCL, H2, PH3, SO2, O3, CL2, HF, which are used in exactly the same way and data format, so you can combine them according to your needs.


Features:

  1. Factory calibrated, accurate measurement
  2. High sensitivity, low power consumption
  3. Excellent stability and anti-interference
  4. Three output modes: I2C, UART and analog
  5. Long service life(2 years)
  6. Compatible with 3.3~5.5V main controllers
  7. 32 modifiable I2C addresses
  8. Reverse connection protection
  9. Temperature compensation
  10. Threshold alarm
  11. It use I2C, UART and analog communication protocol to make smooth commutation between sensor and micro-controller.

Specifications:

  1. Detection Gas: Hydrogen fluoride (HF)
  2. Detection range: 0~10ppm
  3. Working Voltage: 3.3~5.5V DC
  4. Working Current: <5mA
  5. Output Signal: I2C, UART (0~3V), analog voltage
  6. Working Temperature: -20~50℃
  7. Working Humidity: 15~90%RH (non-condensing)
  8. Storage Temperature: -20~50℃
  9. Storage Humidity: 15~90%RH (non-condensing)
  10. Lifespan: >2 years (in the air)
  11. Adapter Plate Size: 37*32mm
  12. Compatibility: Arduino, ESP32, Raspberry pi

Package Includes:

1 x DFRobot Gravity HF Sensor (Calibrated) – I2C, UART and analog

TGS 3870-F00 is a micro-bead type semiconductor gas sensor for the detection of both methane and carbon monoxide. Using a micro-bead gas sensing structure, both methane and carbon monoxide can be detected with a single sensor element by periodic application of two different heater voltages (high and low). Miniaturization of the gas sensing bead results in a heater power consumption of only 38mW (average).

TGS 3870-F00 has low sensitivity to alcohol vapors (a typical interference gas in the residential environment) and has high durability, making the sensor ideal for consumer market gas alarms.

Note: For more technical details go through Datasheet in the attachment section


Features:

  1.  Miniature size and low power consumption
  2.  High sensitivity and selectivity to both
    methane and carbon monoxide (CO)
  3.  Low sensitivity to alcohol vapor
  4.  Long life and low cost

Package Includes:

1 x Figaro TGS3870 Methane/Carbon Monoxide Sensor

Figaro’s TGS5042 is a battery-operable electrochemical sensor which offers several advantages over traditional electrochemical sensors. Its electrolyte is environmentally friendly, it poses no risk of electrolyte leakage, can detect concentrations as high as 1% CO, operates in a range from -5˚ and +55˚C, and it has lower sensitivity to interferant gases. With long life, good long-term stability, and high accuracy, this
sensor is the ideal choice for CO detectors with digital displays. OEM customers will find individual sensor data printed on each sensor in barcode from, enabling users to skip the costly gas calibration process and allowing for individual sensor tracking. TGS5042 utilizes a standard AA battery-sized package.

Note: for more technical details go through Datasheet in the attachment section


Applications:
  1. * Residential and commercial CO detectors
  2. CO monitors for industrial applications
  3.  Ventilation control for indoor parking garages
  4.  Fire detection

Package Includes:

1 x Figaro TGS5042-A00 Carbon Monoxide Sensor Industrial safety

Weight
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Effective distance

0.8m(typ), 1.5m(max)

Voltage (V)

2.5V ~ 5.0V

Application

Obstacle detection, Obstacle-avoiding car

Interface

Digital Output, GND, VCC

Color

Blue

Outline dimension (mm)

47.7mm * 17.9mm

Mounting Hole Diameter (mm)

2.0mm

Operating Temperature Range (°C)

-40~+55℃

Working Humidity Range

15~90%RH(Non-Condensing)

Measure Range

0~100ppm

Response Time ( μS)

≤30000

Model No.

TGS6812-D00

Heater Current

175mA (typical)

Heater power consumption

525mW (typical)

Target Gases

Hydrogen, methane, iso-butane

Test Gas Conditions

Hydrogen/methane/iso-butane in air at 20±2˚C, 65±5%RH

Zero offset

-15 ~ +55mV

Detection Gas

Hydrogen fluoride (HF)

Detection range

0~10ppm

Working Voltage

3.3~5.5V DC

Working Current

<5mA

Working Temperature Range (°C)

-20 to 50

Working Humidity Range

15~90%RH (non-condensing)

Model No.

TGS3870-F00

Circuit Voltage

5.0±0.2V DC pulse

Load Resistance

variable (>0.75kΩ)

Sensing Principle

MOS type

Sensor Resistance

0.3kΩ~5.0kΩ in 3000ppm methane 2kΩ~40kΩ in 200ppm CO

Standard Package

Plastic base and metal can

Target Gases

Methane and Carbon Monoxide

Test Gas Conditions

Target gas in air at 20±2˚C, 65±5%RH

Model No.

TGS5042-A00

Target Gases

Carbon monoxide

Typical detection range

0 ~ 10, 000ppm

Output current in CO

1.2~2.4nA/ppm

Baseline offset(*1)

<±10ppm equivalent

Operating & storage temperature (*2,*3)

-5˚C ~ +55˚C

Operating humidity

5 ~ 99%RH (no condensation)

Response time (T90)

within 60 seconds

Standard test conditions

20±2˚C, 40±10%RH